Products
CLASSIFICATIONXinhongda
instrumentation Professional Quality
Mouse Performance Tester
- Prev > Fully automatic CNC keystroke elasticity curve tester 1-16 stations
- Next > XHD-MS001 Mouse Load Displacement Curve Tester
Machine Characteristics
Mouse performance test machine for gaming mouse button all-round automatic flip online test, through manual loading and unloading will be placed in the product to be tested area, the product is placed after the completion of the software to perform the test action, the end of the action, the product test results of the state of the data color marking display, if the test status is OK, continue to the next mouse button test, if the middle of the NG product, the test item data corresponding to the location of the red highlighting display. After the completion of the mouse point test, the results of the entire number of test points will be a comprehensive judgment.
Machine Features
1 1, realize the mouse signal output travel test;
2, the test document a test to the end, load/travel tolerance with the point can be automatically and accurately switched, followed by OK / NG judgment;
3、 Data-curve integration real-time tracking;
4, the test item category is complete, the algorithm is refined, add that is used;
5, test efficiency 100-150 / h (with the number of test points);
6、Sweeping code gun for mouse identification code entry;
7, SFC upload function according to customer demand (for non-configuration items);
8, microcontroller / software independent research and development;
9, Manual assisted loading and unloading + four-axis degree of freedom flip;
10、 Grating safety protection.
Specification
Product Model | XHD-MS004 |
control system | Self-developed, self-contained control system |
laptops | industrial grade |
Load Cells | 2Kgf (accuracy 0.03‰FS) |
Probe Specifications | One sensor for each 1mm and 2mm diameter probe; |
X/Y translation speed | 50-5000mm/min |
Z-direction movement speed | 0-5000mm/min |
Machine Size | L1400mm*W1400mm*H1800mm |
Using the power supply | 220V,60HZ |
product demand

Schematic diagram of test station


Mouse Button Test Item Category
Test item name in Chinese | Test Item Symbol | Test Item Definition |
Peak point 1 load value (go) | OF/PT | The location of the first peak of the load value in the going range. (The load curve of the going range changes from small to large, when there is a change from large to small and exceeds a certain ratio or force value, this point is captured as the peak position) |
Trough 1 load value (go) | BF/BT | The location of the first valley point of the load value in the going range. (The load curve of the going range goes from small to large, when there is a change from large to small and exceeds a certain ratio or force value, this point is captured as the location of the valley point.) |
Peak point 1 load value (back) | MF/MT | The location of the first load peak in the return stroke. (The load curve of the return trip changes from small to large, when there is a change from large to small and exceeds a certain ratio or force value, this point is captured as the valley point position) |
Valley Point 1 load value (back) | RF/RT | The location of the first valley point of the load value in the going range. (The load curve of the going range goes from small to large, when there is a change from large to small and exceeds a certain ratio or force value, this point is captured as the location of the valley point.) |
Click Force/Rate(go back) | rCf/CC(BACK) | Peak 1 Load (Go) minus Valley 1 Load (Go) is Click Force/Rate (Go). ClickForce divided by Peak 1 Load (Go) multiplied by 100% is Rate. |
pre-departure inflection point (math.) | TP(GO) | Load and travel value of the corner of the going graph, you can set the upper and lower ranges of the travel of the test item, the current default travel upper limit is 0.1 |
outbound leg after the inflection point (math.) | TTF | Load vs. stroke values at the corners of the straight line of the going graphs |
turning point before the return trip | TP(BACK) | The load and travel values for the return graphic corners allow you to set a range of upper and lower travel limits for the test item, currently the default upper travel limit is 0.1; |
post-travel inflection point | rTTF | Load vs. travel values at straight-line corners of return graphs |
Press Slope | K(GO) | (Peak load to destination - load at inflection point before destination) / (Peak travel to destination - travel at inflection point before destination) = k |
slope of rebound | K(BACK) | (return peak load - return pre-inflection load) / (return peak travel - return pre-inflection travel) = k |
Press Slope2 | K2(GO) | Slope of the post-trip inflection point to the value of the trip valley 1 load, (post-trip inflection point load - trip valley 1 load) / (post-trip inflection point trip - trip valley 1 trip) |
Product Diagram


Go Mobile