I. Labeling on the Insertion and Pullout Force Tester Machine
    Danger label: the operator may be injured.
    Warning label: There is a risk of damage to the instrument
    Attention label: may affect the test results and quality
 
Second, the insertion and extraction force test machine operation steps:
    Enter the insertion and extraction force tester software control program, select the travel speed, and then press the panel of the up or down button to adjust the position.
    Select the appropriate fixture and device properly, the insertion and extraction test machine upper and lower safety limit screws set up, especially the upper limit screws set the position of the need to pay attention to avoid when the specimen is pulled off, the insertion and extraction test machine automatically on the various additions, the lower fixture impact on the fixture, resulting in damage to the load yuan.
    After setting the required conditions and specimen specifications, you can start the test.
    Specific aspects of the operation, please follow the insertion and extraction force testing machine operating instructions for operation.
 
C. Precautions:
    1. Due to the insertion and extraction force tester load sensor in the axial force (including push, pull two aspects), more than 120% of the maximum load will be damaged, please be especially careful when operating, in addition to lateral load and impact load also need to be avoided.
    2. The plugging force tester has a complete protection device for the load cell, but the prerequisite is that the connection cable of the load cell must be connected with certainty. In addition, please use the machine under normal program so that the load cell can be fully protected even if high speed movement occurs.
    3. Since the insertion/extraction force tester produced by Jetco Automation is controlled by Windows software interface, it is recommended that you terminate other software programs when using the insertion/extraction force tester to avoid inaccurate test results or misuse due to CPU resources being consumed by multitasking operations.
    4. The use of insertion and extraction force test machine and software control part of the recommended special people dedicated machine, please do not connect to the network, external hardware devices of unknown origin (such as U disk), to avoid causing errors in the software function and the destruction of test data.
 
Fourth, the insertion and extraction force test machine regular maintenance
    1. Keep the set screw of the safety limit switch clean and pay attention to the set position at any time;
    2. Regularly check the insertion and extraction force tester left and right screw, keep a little lubricant;
    3. Absolutely prohibit the test over the insertion and extraction force tester load yuan maximum load of the specimen.